Insulation Calculator — batts, rolls and coverage

Batts, rolls and blown-in by bag count. Bag coverage falls as the target R rises, so the same square footage takes 1.57 bags of R-21 for every bag of R-13.

Bays, the batt width that is actually manufactured for them, and the bag count — with the part that catches people out stated next to the number, because a bag holds less square footage the higher the R-value goes, so an attic never prices like a wall.

Quick answer: which batt width to buy

FramingClear bayBatt width
12 in. o.c., sawn 2×10-1/2 in.11 in.
16 in. o.c., sawn 2×14-1/2 in.15 in. (15-1/4 flangeless)
24 in. o.c., sawn 2×22-1/2 in.23 in. (23-1/4 flangeless)
16 or 24 in., steel or I-joist16 or 24 in.
Any spacing, R-25 and up16 or 24 in.

Batts for sawn framing are made wider than the bay so they friction-fit: 15 in. in a 14-1/2 in. bay. Steel studs, I-joists and every batt from R-25 up are made to the on-center module instead.

Two things decide the answer and neither one is the wall area: how many bays there are, and which batt is actually manufactured for them. Enter the framing and this gives you both, then converts to bags at whatever coverage is printed on the bag you buy.

— — —
The two solid bars are the framing. The dashed outline is the batt, and it is wider than the opening on purpose — half an inch of friction fit on a cavity batt, a full lap over the member on a module-width one. Size it off the clear opening and it falls out; size it off the o.c. spacing in sawn framing and it goes in compressed.
——
Bays—
Pieces—
Width to buy—
Batt thickness—
Depth check—
Area—
To order—
Coverage used—
Bag coverage vs R-13—

What I check on a job

The bag that arrives, not the drawn one. The number I distrust first is not the bag count but the product behind it, because the batt named on the drawings is not always the batt that arrives, and every figure here was worked from the drawn one. The swap that hurts is on steel studs. At 16 inches on center a C-stud leaves about 15-15/16 inches clear, so a 15 or 15-1/4 inch batt made for a wood wall is narrower than the opening, not wider, and it falls out of the bay instead of holding by friction. That is why ROCKWOOL makes its steel-stud batt 16-1/4 inches against 15-1/4 for wood, and why I check which framing the bag was made for before I check its R-value. The bag count carries the same assumption. It was worked from the coverage of the product on the drawings, so when a different product turns up, the count was made for a bag nobody delivered, and I redo it from the one on the pallet.

Spacing options of 12, 16, 19.2 and 24 in on centre are the columns of the IRC span tables for floor joists, ceiling joists and rafters (2021 IRC Tables R502.3.1(1)–(2), R802.4.1(1)–(8), R802.5.1). Walls are a different list: Table R602.3(5) gives maximum stud spacings of 16 and 24 in only, and Table R602.3(6) tabulates 12, 16 and 24 in. 19.2 in appears nowhere in IRC Chapter 6 as a stud spacing, which is why this page flags it on a wall. 19.2 is exact, not rounded. 96 ÷ 5 = 19.2, five bays to an 8 ft sheet.

Clear opening is spacing minus the member. 1-1/2 in is the minimum dressed dry thickness of nominal 2× lumber in US DOC PS 20-25, American Softwood Lumber Standard, Table 3; green surfaced stock is 1-9/16 in, which takes a 16 in o.c. bay to 14-7/16 in. Metric dressed timber is 38 mm, so 400 mm centres give 362 mm clear and 600 mm give 562 mm. Those are computed on the metric module, not converted from the imperial answer. UK and European regularised carcassing is often 47 mm, which changes the opening again. An I-joist presents a 3/8 in web and a steel C-stud presents about 1/16 in, which is why their batts are wider at the same spacing.

Batt widths come from the Owens Corning Thermal Batt FIBERGLAS Product Data Sheet, Pub. No. 17931-J, “Thermal Batt Insulation Technical Data”, which separates the rows and prints the metric equivalents itself: Wood Frame Construction / Walls 15 in (381 mm) and 23 in (584 mm); Wood Frame Roof/Floor/Ceiling R-30 at 16, 19-1/4 (489 mm) and 24 in and R-38 at 16 and 24 in; Metal Frame Construction 16 in (406 mm) and 24 in (609 mm). Cross-checked against the Knauf EcoBatt data sheet (“Forms Available — Wood Frame Construction”, which also lists an 11 in width) and CertainTeed Sustainable Insulation product data (“Available Sizes”: 15, 15-1/4, 19, 23, 23-1/4 in). The quarter-inch-over sizes are the flangeless friction-fit products, faced or not. CertainTeed sells kraft-faced SpeedyR Tabless batts at 15-1/4 in, and Owens Corning stocks no 15-1/4 in wall batt at all. Steel-stud batts run wider still: ROCKWOOL ComfortBatt (technical data sheet, 05-2025) lists 15-1/4 and 23 in for wood but 16-1/4 and 24-1/4 in for steel.

Thicknesses are the standard products in the same data sheets. High-density and high-performance lines reach the same R in less depth: R-21 in 5-1/2 in, R-30C in 8-1/4 in, R-38C in 10-1/4 in. Check the sheet for the product you actually buy. RSI = R × 0.1761 m²·K/W.

Bag coverage is a model here, not a specification. Bags are packed to a roughly fixed compressed volume, so the square footage in a bag falls about in proportion to batt thickness. The default is anchored on one real package, CertainTeed unfaced R-13 at 15-1/4 in × 93 in, 16 pieces. That is 15.25 × 93 × 16 ÷ 144 = 157.58 ft², and it matches the catalogue figure exactly. From there it is scaled by 3-1/2 in ÷ the batt thickness. Real bags vary by maker, R-value and retail pack, and every bag prints its own coverage. Type that number in and the model gets out of the way.

When the run is not a whole number of batts the piece count is given twice: the tight figure assumes the offcut from one bay fills the short end of the next, which a fibreglass offcut will do, and the whole-batt figure assumes it does not. The bag count is worked from the tight figure, so raise the waste allowance if nobody on site is going to splice.

None of this is a takeoff. Corners, king-stud packs, headers, blocking, recessed lights and knee walls all need cutting, the first and last bay of a wall are never the field dimension, and any of it can be overridden by the drawings in front of you.

Worked example

A 40 ft wall with 7'-9" bays at 16" on centre, R-21 batts: how much area and how many bags?

  1. Gross area = 40 × 7.75 = 310 ft².
  2. At 16" o.c. the bays are 14.5 in wide; 93-inch batts fill a 7'-9" bay one per bay.
  3. Bag coverage is printed per bag (100.3 ft² here); order = ceil(310 × 1.10 ÷ 100.3).

310 ft² of wall, 30 bays at 16" o.c., and the bag count the page works out from the printed coverage with 10% waste. Bag coverage falls as R rises, so R-21 takes more bags than R-13 for the same wall.

2 values on this page were driven in a browser and compared with independently derived figures on 2026-10-29 (2808 values across 228 calculators site-wide).

Questions

Why does bag coverage change with the R-value?

A bag holds a fixed amount of material, and a higher R-value batt is thicker or denser, so each bag covers less area. The coverage printed on the bag is the figure to use.

How wide is a batt for 16-inch framing?

15 inches for a 14½-inch clear bay; 23 inches for 24-inch framing. Batts are cut for the bay, not the spacing.

Can wall studs be at 19.2 in. on centre?

The IRC's wall tables do not list it: Table R602.3(5) gives 16 and 24 in. and Table R602.3(6) gives 12, 16 and 24 in. 19.2 in. (96 ÷ 5, five bays to an 8 ft sheet) appears only in the joist and rafter span tables, which is why the page flags it on a wall.

Why does 400 mm spacing leave 362 mm and not 381?

Because metric dressed timber is 38 mm thick, so the clear bay is 400 − 38 = 362 mm, and 600 mm gives 562. The page computes the metric module itself rather than converting the imperial answer; regularised UK timber at 47 mm changes the opening again.